Internal combustion engine control cabinet

Categories

Examples of production orders

Control and monitoring systems Controllers Sensors and measurement systems Antenna amplifiers Other devices Software Automation

Internal combustion engine control cabinet

PLC: ECU

Digital inputs: 12

Analogue inputs: 15

Digital outputs: 24

Analogue outputs: 6

Functionality:

Monitoring of power supply voltages, monitoring of protection tripping, oil temperature control, visualization, recording of exhaust gas temperatures and control of injectors.

Scope of completed work:

Schematic diagram, assembly diagram, construction of control cabinet for the installation of ECU, installation, commissioning and configuration of injector signal amplifiers.