Internal combustion engine control cabinet
Categories
Examples of commissioned projects
Examples of production orders
Internal combustion engine control cabinet
PLC: ECU
Digital inputs: 12
Analogue inputs: 15
Digital outputs: 24
Analogue outputs: 6
Functionality:
Monitoring of power supply voltages, monitoring of protection tripping, oil temperature control, visualization, recording of exhaust gas temperatures and control of injectors.
Scope of completed work:
Schematic diagram, assembly diagram, construction of control cabinet for the installation of ECU, installation, commissioning and configuration of injector signal amplifiers.
All of our solutions have one thing in common –
perfection arising from the passion and commitment of those who create them.
Any questions?